Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Res ; 38(7): 1627-1636, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32369210

RESUMO

The aim of this study was to obtain micro-computed tomography derived measurements of the rat proximal femur, to create parameterized rat hip implants that could be surgically installed in a clinically representative small animal model of joint replacement. The proximal femoral anatomy of N = 25 rats (male, Sprague-Dawley, 390-605 g) was quantified. Key measurements were used to parameterize computer-aided design models of monoblock rat femoral implants. Linear regression analysis was used to determine if rat hip dimensions could be predicted from animal weight. A correlation analysis was used to determine how implants could be scaled to create a range of sizes. Additive manufacturing (3D printing) was used to create implants in medical-grade metal alloys. Linear regressions comparing rat weight to femoral head diameter and neck-head axis length revealed a significant nonzero slope (P < .05). Pearson's correlation analysis revealed five significant correlations between key measurements in the rat femur (P < .05). Implants were installed into both cadaveric and live animals; iterative design modifications were made to prototypes based on these surgical findings. Animals were able to tolerate the installation of implants and were observed ambulating on their affected limbs postoperatively. Clinical significance: We have developed a preclinical rat hip hemiarthroplasty model using image-based and iterative design techniques to create 3D-metal printed implants in medical-grade metal alloys. Our findings support further development of this model for use as a low-cost translational test platform for preclinical orthopaedic research into areas such as osseointegration, metal-on-cartilage wear, and periprosthetic joint infection.


Assuntos
Fêmur , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Impressão Tridimensional , Animais , Artroplastia de Quadril , Peso Corporal , Hemiartroplastia , Masculino , Ratos Sprague-Dawley , Microtomografia por Raio-X
2.
Am J Vet Res ; 73(10): 1665-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23013195

RESUMO

OBJECTIVE: To compare effects of sterilization with hydrogen peroxide gas plasma (HPGP), ethylene oxide, and steam on bioadhesive properties of nylon and polyethylene lines used for stabilization of canine stifle joints. SAMPLE: Samples of a 36.3-kg test nylon leader line, 57.8-kg test nylon fishing line, and 2-mm ultrahigh-molecular weight polyethylene (UHMWPE) were used. PROCEDURES: In this in vitro study, samples of nylon leader line, fishing line, and UHMWPE sterilized by use of HPGP, ethylene oxide, and steam or unsterilized samples were used. Bacterial adherence on unsterilized and sterilized samples was tested with Staphylococcus epidermidis and Escherichia coli. Five samples were examined for each line type and sterilization condition, and final colony counts were obtained. RESULTS: Bacterial adherence was significantly affected by method of sterilization for all 3 line types. For most of the samples, bacterial adherence was similar or lower when HPGP sterilization was used, compared with results for sterilization via ethylene oxide and steam, respectively. Bacterial adherence was significantly higher for UHMWPE, compared with adherence for the nylon line, regardless of the sterilization method used. Bacterial adherence was higher for nylon fishing line than for nylon leader line for S epidermidis after ethylene oxide sterilization and for E coli after HPGP and ethylene oxide sterilization. CONCLUSIONS AND CLINICAL RELEVANCE: Effects of HPGP sterilization on bioadhesive properties of nylon and polyethylene lines compared favorably with those for ethylene oxide and steam sterilization. Also, nylon line may be a more suitable material than UHMWPE for suture prostheses on the basis of bacterial adherence properties.


Assuntos
Aderência Bacteriana , Nylons/química , Polietilenos/química , Esterilização/métodos , Joelho de Quadrúpedes/cirurgia , Suturas/veterinária , Animais , Doenças do Cão/cirurgia , Cães/cirurgia , Escherichia coli/crescimento & desenvolvimento , Escherichia coli/fisiologia , Óxido de Etileno/química , Peróxido de Hidrogênio/química , Instabilidade Articular/cirurgia , Instabilidade Articular/veterinária , Teste de Materiais/veterinária , Gases em Plasma/química , Staphylococcus epidermidis/crescimento & desenvolvimento , Staphylococcus epidermidis/fisiologia , Vapor/análise , Técnicas de Sutura/veterinária
3.
BMC Vet Res ; 8: 87, 2012 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-22726641

RESUMO

BACKGROUND: Understanding normal gait requires allowing for variations in normal patterns by the sex, age, and species in question. Therefore, the aim of this study was to evaluate kinetic and temporospatial parameters in clinically healthy sheep from three different age groups with a pressure-sensing walkway. The sheep were judged to be healthy based on the results of complete physical and orthopaedic examinations and had no history of lameness. Twenty-one clinically healthy female Santa Ines sheep were divided into three groups: G1 - seven animals, aged from 8 to 12 months and weighing 19.5-33 kg; G2 - seven individuals, aged from 2 to 4 years and weighing 26.5-42 kg; and G3 - seven sheep, aged more than 5 years and weighing 37.3-45 kg. The animals were examined from two directions: first on the left side and then on the right side of the handler. The data from the first five valid trials in each direction were collected for each sheep and analysed using the designated software. A trial was considered valid if the sheep walked within the correct velocity (1.1-1.3 m/s) and acceleration (from -0.15 to 0.15 m/s2) ranges. The peak vertical force (PVF), vertical impulse (VI), gait cycle time, stance time, swing time, stride length, and the percentage body weight distribution among the four limbs were determined. RESULTS: No significant differences were observed, in either the forelimbs or the hind limbs, between the left and right sides or between the two directions for any of the variables. No significant temporospatial differences were found among the groups. Significant PVF (%BW) differences were observed in the forelimbs (G1>G3) and hind limbs (G1>G3), and significant VI differences were observed in the forelimbs (G1>G3). CONCLUSIONS: Young healthy sheep differ from older sheep in the vertical forces they create when walking at the same velocity on a pressure-sensing walkway.


Assuntos
Envelhecimento/fisiologia , Marcha/fisiologia , Ovinos/fisiologia , Caminhada/fisiologia , Animais , Fenômenos Biomecânicos , Feminino , Membro Anterior/fisiologia , Membro Posterior/fisiologia , Pressão
4.
J Vet Diagn Invest ; 23(5): 1037-40, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21908371

RESUMO

A male German Shepherd Dog mix was presented for chronic non-weight-bearing lameness of the left hind limb. At clinical examination, the dog's left hind limb had severe joint contractures, with the presence of what appeared to be a second paw. The dog also had 2 sets of external genitalia of opposite phenotypic sex; a complete male reproductive tract with a left retained testicle and a right descended testicle, as well as rudimentary female external genitalia including a hypoplastic vulva with a blind-end vagina and a hypertrophied clitoris. The female genitalia were located on the proximal posterior third of the deformed limb. Following amputation of the hind limb, gross pathologic analysis revealed a duplication of the fibula, tarsal, and metatarsal bones, digits, and appendices. The supernumerary structures and female genitalia were concluded to represent a parasitic twin. As conjoined or parasitic twinning of non-identical twins is thought to be impossible, the presence of genitalia of opposite phenotypic sex appeared paradoxical. Polymerase chain reaction analyses were therefore performed to determine the genotypic sex of both animals, which revealed the presence of the Y chromosome in all tissues, including the female genitalia. The non-masculinization of the external genitalia in the parasitic twin was presumed to be the result of an embryonic developmental defect. On this basis, a diagnosis of atypical caudal duplication (parasitic twinning) with phenotypic sex reversal was made.


Assuntos
Transtornos do Desenvolvimento Sexual/veterinária , Doenças do Cão/congênito , Gêmeos Unidos/patologia , Animais , Cães , Masculino , Análise para Determinação do Sexo
5.
J Vet Dent ; 27(4): 212-21, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21322428

RESUMO

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws of free angulation were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the favorable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique fractures, without compromising mandibular dental or neurovascular structures.


Assuntos
Placas Ósseas/veterinária , Técnicas de Fixação da Arcada Osseodentária/veterinária , Fraturas Mandibulares/veterinária , Animais , Fenômenos Biomecânicos , Placas Ósseas/normas , Cadáver , Simulação por Computador , Análise do Estresse Dentário/veterinária , Cães , Análise de Elementos Finitos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Imageamento Tridimensional , Técnicas de Fixação da Arcada Osseodentária/instrumentação , Modelos Lineares , Masculino , Fraturas Mandibulares/diagnóstico , Fraturas Mandibulares/cirurgia , Resistência à Tração , Tomografia Computadorizada por Raios X/veterinária
6.
J Vet Dent ; 25(1): 16-22, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18512621

RESUMO

A consecutive series of cases of dogs and cats with locked jaw syndrome (inability to open or close the mouth) are reported in this study. Dogs were significantly overrepresented (84.0%) and adult dogs were more frequently affected (81.0%). Temporomandibular joint ankylosis due to fracture was the most common cause (54.0%) of locked jaw syndrome. Additional potential causes of locked jaw syndrome are masticatory muscle myositis, neoplasia, trigeminal nerve paralysis and central neurological lesions, temporomandibular joint luxation and dysplasia, osteoarthritis, retrobulbar abscess, tetanus, and severe ear disease. Treatment of locked jaw is directed towards the primary cause. It is important to treat the tonic spasm in order to minimize periarticular fibrosis. Surgical intervention is recommended for temporomandibular joint ankylosis. Masticatory muscle myositis treatment is initiated by gradually opening the mouth, with medical treatment based on immunosuppressive therapy. Fracture and masticatory muscle myositis are associated with a relatively good prognosis in regard to short-term outcome as compared to animals with central neurologic lesions or osteosarcoma which have a poor prognosis.


Assuntos
Doenças do Gato/epidemiologia , Doenças do Cão/epidemiologia , Síndrome da Disfunção da Articulação Temporomandibular/veterinária , Animais , Doenças do Gato/etiologia , Doenças do Gato/terapia , Gatos , Doenças do Cão/etiologia , Doenças do Cão/terapia , Cães , Feminino , Illinois/epidemiologia , Masculino , Registros , Estudos Retrospectivos , Síndrome da Disfunção da Articulação Temporomandibular/epidemiologia , Medicina Veterinária
7.
Vet Surg ; 33(5): 495-504, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15362988

RESUMO

OBJECTIVE: To create a model in sheep for investigation of early changes related to the formation of an interface membrane in hip prosthesis. STUDY DESIGN: Experimental study. ANIMALS: Twenty-four female adult Swiss Alpine sheep. METHODS: Sheep were divided into 2 groups of 12 for unilateral cemented total hip arthroplasty. In Group I, the prosthesis was fixed with retrograde cement gun injection to achieve a complete cement mantle, whereas in Group II a primary cement mantle defect was produced. Groups I and II were further divided into 2 sub-groups with study end points of 2 and 8.5 months after surgery. Radiographs were evaluated postoperatively and at euthanasia for migration of the femoral component and bone resorption. Histologic sections were evaluated semiquantitatively for changes in cell types and numbers, and bone reactions; and quantitatively for size of interface membrane and new bone formation. RESULTS: Radiographically, there tended to be an increase in bone resorption and periosteal bone formation throughout the femoral shaft in Group II compared with Group I, but this was only statistically significant at the region of the femoral neck (R5) at both time periods (P<.05). Semiquantitative histologic evaluation revealed significant increases (P<.05) in cellularity, numbers of fibroblasts, giant cells, macrophages, and mononuclear cells, in Group II primarily at 2 months after surgery. This was also true for interface membrane formation and bone remodeling. Quantitative data showed an increased in the size of the interface membrane and area of bone formation at 8.5 months in Group II. CONCLUSIONS: The cement defect model offered controlled and repeatable production of an interface membrane. The results suggest that a primary cement mantle defect could be a possible trigger for implant instability, eliciting a cascade of biomechanical and molecular events in bone tissue leading to aseptic loosening. CLINICAL RELEVANCE: The results show the effect of defects in the cement mantle in promoting interface membrane formation. Long-term and biochemical studies are required to evaluate the relevance of this interface membrane formation.


Assuntos
Artroplastia de Quadril/veterinária , Cimentos Ósseos , Prótese de Quadril/veterinária , Modelos Animais , Animais , Artroplastia de Quadril/métodos , Remodelação Óssea , Feminino , Teste de Materiais , Desenho de Prótese , Ovinos
8.
BMC Musculoskelet Disord ; 5: 7, 2004 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-15113432

RESUMO

BACKGROUND: Aseptic loosening of hip prosthesis as it occurs in clinical cases in human patients was attributed to wear particles of the implants, the response of the tissue dominated by macrophages and the production of inflammatory mediators and matrix degrading enzymes; however, the cascade of events initiating the process and their interaction regarding the time course is still open and discussed controversially. Therefore, the goal of this study was to establish an experimental animal model in sheep allowing to follow the cascade of early mechanical and biochemical events within the interface membrane and study the sequence of how they contribute to the pathological bone resorption necessary for aseptic loosening of the implant. METHODS: A cemented modular system (Biomedtrix) was used as a hip replacement in 24 adult Swiss Alpine sheep, with one group receiving a complete cement mantle as controls (n = 12), and the other group a cement mantle with a standardized, lateral, primary defect in the cement mantle (n = 12). Animals were followed over time for 2 and 8.5 months (n = 6 each). After sacrifice, samples from the interface membranes were harvested from five different regions of the femur and joint capsule. Explant cell cultures were performed and supernatant of cultures were tested and assayed for nitric oxide, prostaglandin E2, caseinolytic and collagenolytic activity. RNA extraction and quantification were performed for inducible nitric oxide synthase, cyclooxygenase-2, interleukin 1, and interleukin 6. Overall differences between groups and time periods and interactions thereof were calculated using a factorial analysis of variance (ANOVA). RESULTS: The development of an interface membrane was noticed in both groups at both time points. However, in the controls the interface membrane regressed in thickness and biological activity, while both variables increased in the experimental group with the primary cement mantle defect over time. Nitric oxide (NO) and PGE2 concentrations were higher in the 8.5 months group (P < 0.0001) compared to the 2 months group with a tendency for the unstable group to have higher concentrations. The same was true for collagenolytic activity (P = 0.05), but not for caseinolytic activity that decreased over time (P < 0.0001). CONCLUSION: In this study, a primary cement mantle defect of the femoral shaft elicited biomechanical instability and biochemical changes over time in an experimental animal study in sheep, that resembled the changes described at the bone cement-interface in aseptic loosening of total hip prosthesis in humans. The early biochemical changes may well explain the pathologic bone resorption and formation of an interface membrane as is observed in clinical cases. This animal model may aid in future studies aiming at prevention of aseptic loosening of hip prosthesis and reflect some aspects of the pathogenesis involved.


Assuntos
Cabeça do Fêmur/química , Prótese de Quadril , Modelos Animais , Falha de Prótese , Análise de Variância , Animais , Artroplastia de Quadril , Cimentos Ósseos , Reabsorção Óssea/etiologia , Dinoprostona/análise , Feminino , Membranas/química , Metaloproteases/análise , Óxido Nítrico/análise , Reação em Cadeia da Polimerase/métodos , Ovinos , Transcrição Gênica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...